Page 8
trol voltage out of the current sensor to the two-pin plug-in con-
nector on the VS-1006. The VS-1006 can sense AC or DC so
polarity is not critical.
3. Connect the 4-circuit mini plug from the VS-1006 to the sensor
input on the MRX-1 rear panel.
4. Plug the power cord on the current sensing device into an
unswitched AC outlet.
5. Once the system has been powered up, the VS-1006 Power LED
should illuminate Red.
6. To test Voltage Sensing, turn the Sensed Device on. The Sensor
LED on the MRX-1 front panel should illuminate in blue. Turn
the Sensed Device off and the LED should turn off as well. If not,
check the connections and measure the device control out with a
volt meter to confirm voltage output. Also confirm that the
Sensed Device’s Power Cord is connected to a Sensed Outlet.
VID-6 Video Sensor Cable
The Video Sensor Cable VID-6 is a special cable for sensing com-
posite video. When composite video is detected, the MRX-1 recog-
nizes that the connected device is ON. System Power ON/OFF
macros, conditional IF/ELSE Smart Macros and other control modes
are typically associated with the status of these sensor inputs. When
an ON condition is detected at the sensor input, the corresponding
Front Panel Sensor LED will illuminate in blue to indicate the ON
condition. Not all devices turn the composite video output off when
in standby, some switch to a black screen. A black screen looks off
and protects some types of video displays from ‘burn in’, but there
is still a sync code present that is not compatible with video sensing
for ON/OFF status. For devices that output a black screen, use a
Voltage Power Sensor from a switched outlet (or status output on the
device if available), a sensed AC outlet that outputs 12V or discrete
IR ON/OFF codes or RS-232 commands.
Connection
Composite
Video (VID-6 Video Sensor Cable)
1. Connect the MALE end of a single male to two female RCA plug
‘Y’ Adapter to the Composite Video Out on the device to be
sensed.
2. Connect the RCA Plug end of the VID-6 Sensor Cable to one of
the jacks on the Y Adapter.
3. Connect the 4-circuit mini plug end of the VID-6 cable to the
Sensor input on the MRX-1 Rear panel.
4. Connect the Second Jack on the Y adapter to the appropriate
MRX-1 BASE STATION